Operation Manual

User Manual of Network Camera
© Hikvision Digital Technology Co., Ltd. All Rights Reserved.
88
1. Enter RS-232 Port Setting interface:
Configuration> Advanced Configuration> System > RS232
Figure 10-16 RS-232 Settings
Note: If you want to connect the camera by the RS-232 port, the parameters of the
RS-232 should be exactly the same with the parameters you configured here.
2. Click to save the settings.
10.8 RS-485 Settings
Purpose:
The RS-485 serial port is used to control the PTZ of the camera. The configuring of
the PTZ parameters should be done before you control the PTZ unit.
Steps:
1. Enter RS-485 Port Setting interface:
Configuration> Advanced Configuration> System > RS485
Figure 10-17 RS-485 Settings
2. Set the RS-485 parameters and click to save the settings.
By default, the Baud Rate is set as 9600 bps, the Data Bit is 8, the stop bit is 1 and
the Parity and Flow Control is None.
Note: The Baud Rate, PTZ Protocol and PTZ Address parameters should be exactly
the same as the PTZ camera parameters.