Quick Start Guide
Table Of Contents
- About This Document
- Chapter 1 Activating and Accessing to the Camera
- Chapter 2 Setting Local Parameters and Network
- Chapter 3 Live View
- Chapter 4 PTZ Control
- 4.1 Operating PTZ Control
- 4.2 PTZ Configuration
- 4.2.1 Configuring Basic PTZ Parameters
- 4.2.2 Configuring PTZ Limits
- 4.2.3 Configuring Initial Position
- 4.2.4 Configuring Park Action
- 4.2.5 Configuring Privacy Mask
- 4.2.6 Configuring Scheduled Tasks
- 4.2.7 Clearing PTZ Configurations
- 4.2.8 Configuring PTZ Control Priority
- 4.2.9 Configuring Panorama Tracking
- 4.2.10 Rapid Focus
- Chapter 5 Storage and Playback
- Chapter 6 Events Settings
- Chapter 7 System Settings
- Appendix
- Appendix 1 SADP Software Introduction
- Appendix 2 Statics, Interference Lightning and Surge Protection
- Appendix 3 Waterproof
- Appendix 4 Bubble Maintenance
- Appendix 5 RS-485 Bus Connection
- Appendix 6 24VAC Wire Gauge & Transmission Distance
- Appendix 7 12VDC Wire Gauge & Transmission Distance
- Appendix 8 Table of Wire Gauge Standards
- Appendix 9 Alarm In/Out Connections
- Appendix 10 Camera Function Description
User Manual of PanoVu Series Network Camera
78
Steps:
1. Enter the audio exception detection interface:
Configuration > Event > Smart Event > Audio Exception Detection
Figure 6-12 Audio Exception Detection
2. Check the Audio Loss Detection checkbox to enable the audio input exception detection.
3. Check the Sudden Increase of Sound Intensity Detection checkbox to enable the sudden rise
detection.
Sensitivity: Range [1-100], the smaller the value the more severe the sound change will trigger
the detection.
Sound Intensity Threshold: Range [1-100], it can filter the sound in the environment, the louder
the environment sound, the higher the value should be. You can adjust it according to the actual
environment.
4. Check the Sudden Decrease of Sound Intensity Detection checkbox to enable the sudden drop
detection.
Sensitivity: Range [1-100], the smaller the value the more severe the sound change will trigger the
detection.
5. Click tab to enter the arming schedule setting interface. The time schedule
configuration is the same as the settings of the arming schedule for motion detection. Refer to Step
5 in Section 6.1.1 Configuring Motion Detection.
6. Click tab to select the linkage method taken for the video loss alarm. Send Email,
Notify Surveillance Center, Trigger Alarm Output, and Trigger Recording are selectable. Refer to
Step 3 in Section 6.1.1 Configuring Motion Detection.
7. Click to save the settings.