Quick Start Guide

19
18
Alarm Input and Output
Connection
Alarm Input:
The network camera can be connected with alarm inputs (0 to 5
VDC).
Alarm output:
The alarm provides the relay output, and the external power
supply is required when it connects to the alarm device.
For DC power supply (left diagram), the input voltage must be
no more than 30VDC, 1A.
For AC power supply, the external relay must be used (right
diagram) to prevent damages to the camera and avoid risk of
electric shock.
JQC-
3FG
Relay
30VDC
GND OUT
L N
220V AC
Relay Output
Dome
( 10 A 250VAC)
Diagram (left) Diagram(right)
1A
OUT(n)
OUT(n)
+
-
DC
DC Load
Relay Output
Dome
OUT(n)
OUT(n)