Quick Start Guide
19
18
Alarm Input and Output
Connection
Alarm Input:
The network camera can be connected with alarm inputs (0 to 5
VDC).
Alarm output:
The alarm provides the relay output, and the external power
supply is required when it connects to the alarm device.
• For DC power supply (left diagram), the input voltage must be
no more than 30VDC, 1A.
• For AC power supply, the external relay must be used (right
diagram) to prevent damages to the camera and avoid risk of
electric shock.
JQC-
3FG
Relay
30VDC
GND OUT
L N
~
220V AC
Relay Output
Dome
( 10 A 250VAC)
Diagram (left) Diagram(right)
1A
OUT(n)
OUT(n)
+
-
DC
DC Load
Relay Output
Dome
OUT(n)
OUT(n)