Data Sheet

Specification
Thermal Module
Vanadium Oxide Uncooled Focal Plane Arrays
160 × 120 (the resolution of output image is 320 × 240)
17 μm
8 μm to 14 μm
Less than 40 mK (25°C), F# = 1.1
1.8 mm
9.44 mrad
90° × 66.4° (H × V)
0.1 m
F1.1
Optical Module
2688 × 1520
1/2.7" Progressive Scan CMOS
Color: 0.0176 Lux @ (F2.25, AGC ON), B/W: 0.0035 Lux @ (F2.25, AGC ON)
1s to 1/100,000s
2.1 mm
119.34° × 93.3°(H × V)
120 dB
IR cut filter with auto switch
Image Function
Fusion view of thermal view and overlaid details of the optical channel
Combines details of thermal and optical image PIP, overlay thermal image on optical
image
Smart Function
4 VCA rule types (Line Crossing, Intrusion, Region Entrance, and Region Exiting), up to
8 VCA rules totally.
3 temperature measurement rule types, 21 rules (10 points, 10 areas, and 1 line).
-20 °C to +150 °C (-4 °F to +302 °F)
± 8 °C (± 14.4 °F)
Dynamic fire point detection, up to 10 fire points detectable.
Infrared
Up to 15 m
Automatically adjusted
Network
Visible Light: 50Hz: 25fps (2688 × 1520), 25fps (1920 × 1080), 25fps (1280 × 720)
Visible Light: 60Hz: 30fps (2688 × 1520), 30fps (1920 × 1080), 30fps (1280 × 720)
Thermal: 1280 × 720, 704 × 576, 640 × 480, 352 × 288, 320 × 240