Configuration Guide
Thermal VCA Configuration guidance
Contens
Thermal VCA Configuration guidance .......................................................................................................1
Chapter 1 VCA better performance configuration suggestions ..................................2
1. Max Distance of VCA Trigger Alarm .......................................................................................2
2. VCA Main Configuration Recommendation .......................................................................2
Chapter2 VCA Common Issues troubleshooting and solutions ...................................7
【False Alarm】 ..........................................................................................................................................7
1. Unmathed target box caused false alarm .......................................................................7
2. Animal false alarm from near side .......................................................................................8
3. Random box false alarm ...........................................................................................................8
4. Device shaking false alarm ......................................................................................................9
【Missing Alarm】 .................................................................................................................................. 10
1. Low temperature difference ................................................................................................. 10
2. Narrow Scene missing alarm ............................................................................................... 10