3)  Blackbody Installation 
Installation location: 
The recommended distance between the camera and the blackbody is in the above 
table.  The  blackbody  is  recommend  to  be  installed  at  a  height  of  1.7m,  with  an 
elevation angle of within 15°. Ensure that the black body appears in the upper left / 
upper right corner of the camera view. Make sure that the blackbody would not be 
blocked by any other target during temperature measurement. 
Configuration Steps: 
1.  Device start-up; 
2.  Press SEL for temperature setting, Press UP and DOWN to adjust the 
temperature of the blackbody as 40 Degrees Celsius; 
3.  Confirm your adjustment by pressing SEL again; 
4.  Wait until the displayed temperature value reaches 40 Degrees Celsius and 
remain unchanged. 