8.  Select the thermal camera channel (normally as Camera 02). 
9.  Configure the following settings: 
  Black Body Parameters: If no blackbody is used in this scheme, uncheck this box. 
  Body Temperature Compensation: Compensate the measured value according 
to the real-time environment temperature. 
  Enable: Check this box to enable body temperature compensation 
  Compensation Type: Setting as Auto is suggested; in this way, auto 
compensation and manual calibration value would both added to the 
measured value. 
  Manual Calibration: The set value would be added to the measured value. 
(If this value is set as 2 degrees Celsius and the measured value is 35 degrees 
Celsius, the displayed value would be 37 degrees Celsius). See Manual 
Calibration part in below for details.   
  Environment Temperature: Setting as Auto is suggested; in this way, the 
environment temperature would be automatically measured. 
10. Click Save. 
4)  Manual Calibration 
Purpose: 