8. Select the thermal camera channel (normally as Camera 02).
9. Configure the following settings:
Black Body Parameters: If no blackbody is used in this scheme, uncheck this box.
Body Temperature Compensation: Compensate the measured value according
to the real-time environment temperature.
Enable: Check this box to enable body temperature compensation
Compensation Type: Setting as Auto is suggested; in this way, auto
compensation and manual calibration value would both added to the
measured value.
Manual Calibration: The set value would be added to the measured value.
(If this value is set as 2 degrees Celsius and the measured value is 35 degrees
Celsius, the displayed value would be 37 degrees Celsius). See Manual
Calibration part in below for details.
Environment Temperature: Setting as Auto is suggested; in this way, the
environment temperature would be automatically measured.
10. Click Save.
4) Manual Calibration
Purpose: