Chapter 4 Body Thermography
Body Thermography function can detect temperature of human face or body in the scene, and
output alarm if the temperature is higher than the setting value.
4.1 Set Body Thermography Parameters
Configure the parameters of body temperature measurement.
Before You Start
Go to Configuration System Maintenance VCA Resource Type, select Body
Thermography.
Steps
1. Go to Configuration Temperature Measurement Basic Settings to configure parameters.
Enable Temperature Measurement
Check to enable temperature measurement function.
Enable Color-Temperature
Check to display Temperature-Color Ruler in live view.
Display Temperature Info. on Stream
Check to display temperature information on the stream.
Add Original Data on Capture
Check to add data on alarm triggered capture of thermal channel.
Add Original Data on Stream
Check to add original data on thermal view.
Data Refresh Interval
It means the refresh interval of temperature information.
Unit
Display temperature with Degree Celsius (°C)/Degree Fahrenheit (°F)/Degree Kelvin (K).
Temperature Range
Select the temperature measurement range.
Distance:
Set the distance between device and the target.
Emissivity
Set the emissivity of your target.