User Manual
Table Of Contents
- Chapter 1 Overview
- Chapter 2 Device Activation and Accessing
- Chapter 3 Temperature Measurement
- Chapter 4 Body Thermography
- Chapter 5 Event and Alarm
- Chapter 6 Arming Schedule and Alarm Linkage
- Chapter 7 Live View
- Chapter 8 Video and Audio
- 8.1 Video Settings
- 8.2 Display Settings
- 8.2.1 Image Adjustment
- 8.2.2 Image Adjustment (Thermal Channel)
- 8.2.3 Exposure Settings
- 8.2.4 Day/Night Switch
- 8.2.5 Set Supplement Light
- 8.2.6 BLC
- 8.2.7 WDR
- 8.2.8 White Balance
- 8.2.9 DNR
- 8.2.10 Set Palette
- 8.2.11 Set Target Color
- 8.2.13 DDE
- 8.2.14 Brightness Sudden Change
- 8.2.15 Enhance Regional Image
- 8.2.16 Mirror
- 8.2.17 Video Standard
- 8.2.18 Digital Zoom
- 8.3 OSD
- 8.4 Set Privacy Mask
- 8.5 Overlay Picture
- 8.6 Set Manual DPC (Defective Pixel Correction)
- 8.7 Set Picture in Picture
- Chapter 9 Video Recording and Picture Capture
- Chapter 10 Network Settings
- Chapter 11 System and Security
- 11.1 View Device Information
- 11.2 Search and Manage Log
- 11.3 Import and Export Configuration File
- 11.4 Export Diagnose Information
- 11.5 Reboot
- 11.6 Restore and Default
- 11.7 Upgrade
- 11.8 View Open Source Software License
- 11.9 Time and Date
- 11.10 Set RS-232
- 11.11 Set RS-485
- 11.12 Set Same Unit
- 11.13 Security
- 11.14 User and Account
- Chapter 12 Appendix
Thermal & Optical Bi-spectrum Network Camera User Manual
13
Note
Refer to the emissivity table for reference in the manual or online.
Version
View the version of current algorithm.
2. Click Save.
4.2 Set Body Thermography
4.2.1 Measure Body Temperature in Thermal Channel
Steps:
1. Go to Configuration → Body Thermography → Body Thermography Configuration.
2. Select thermal channel.
3. Click Draw Area, then click the mouse on the black body in live view and save it.
4. Set the black body parameters.
Emissivity: Set the emissivity of black body.
Note
Refer to the emissivity table for reference in the manual or online.
Distance: The straight-line distance between the black body and the device.
Temperature: Enter the temperature of the black body.
5. Set Environmental Temperature Mode. Auto and Manual are selectable. In auto mode, the
device detects environment temperature automatically. In manual mode, you should enter
environment temperature manually.
6. Set the body temperature compensation parameters if you need to detect human body
temperature instead of shell temperature.
i. Enable body temperature compensation function.
ii. Select the compensation type.
iii. In auto mode, the device calculates compensation value automatically. If the detected
body temperature is still inaccuracy, you can set Manual Calibration value.
iv. In manual mode, you should enter Manual Calibration value, and corresponding
compensation value displays in Compensation Value field.
7. Click Save.