3.3.1 Set Thermography Parameters
Congure the parameters of temperature measurement.
Before You Start
Go to Conguraon → System → Maintenance → VCA Resource Type , select Temperature
Measurement+Behavior Analysis.
Steps
1.
Go to
Conguraon → Local , enable Display Temperature Info. .
Display Temperature Info.
Select Yes to display temperature informaon on live view.
Enable Rules to display the rules informaon on live view.
2. Click Save.
3. Go to
Conguraon → Temperature Measurement → Basic Sengs to congure parameters.
Enable Temperature Measurement
Check to enable temperature measurement funcon.
Enable Color-Temperature
Check to display Temperature-Color Ruler in live view.
Display Temperature Info. on Stream
Check to display temperature
informaon on the stream.
Display Temperature in Opcal Channel
Check to display thermal channel temperature informaon in the opcal channel.
Display Max./Min./Average Temperature
Check to display maximum/minimum/average temperature informaon on liveview when
the temperature measurement rule is line or area.
Posion of Thermometry Info
Select the posion of temperature informaon showed on the live view.
Near Target: display the
informaon beside the temperature measurement rule.
Top Le: display the informaon on the top le of screen.
Add Original Data on Capture
Check to add data on alarm triggered capture of thermal channel.
Add Original Data on Stream
Check to add original data on thermal view.
Data Refresh Interval
It means the refresh interval of temperature informaon.
Unit
Display temperature with Degree Celsius (°C)/Degree Fahrenheit (°F)/Degree Kelvin (K).
Thermal & Opcal Bi-spectrum Network Camera User Manual