User's Manual

Table Of Contents
3.3.3 Set Expert Mode
Select the temperature measurement rules from Point, Line, or Area and congure parameters,
the device alarms if the alarm rules are met.
Steps
1. Go to
Conguraon → Temperature Measurement → Basic Sengs , check Enable
Temperature Measurement.
2. Refer to Set Thermography Parameters to set the parameters.
3. Go to
Conguraon → Temperature Measurement → Advanced Sengs , select Expert.
4. Select and enable the temperature measurement rules. Please refer to Set Thermography Rule
for
seng the rule.
5.
Oponal: Click Area's Temperature Comparison to set the alarm rules and the temperature.
6. Refer to Set Arming Schedule for seng scheduled me. Refer to Linkage Method Sengs for
seng linkage method.
7. Click Save.
The maximum temperature and thermography rules will be displayed on the liveview.
Note
Go to Image → VCA Rules Display to adjust the fonts size and the temperature colour of
normal, alarm and pre-alarm.
3.3.4 Set Thermography Rule
Steps
1. Customize the rule name.
2. Select the rule type to Point, Line, or Area. Then draw a point, line, or area on the interface
where the
posion to be measured.
Point
Please refer to Point Thermography for detailed conguraon.
Line Please refer to Line Thermography for detailed conguraon.
Area Please refer to Area Thermography for detailed conguraon.
3. Congure the temperature measurement parameters.
Emissivity
Set the emissivity of the target. The emissivity of the surface of a material is its eecveness
in eming energy as thermal radiaon. Dierent objects have dierent emissivity. Refer to
Common Material Emissivity Reference to search for the target emissivity..
Distance
The distance between the target and the device.
Reecve Temperature
Thermal & Opcal Bi-spectrum Network Camera User Manual
9