User's Manual

Table Of Contents
Chapter 4 Fire Source Detecon
The device will trigger and upload alarm when detect the re source or smoking.
Fire source
detecon includes re source detecon and smoking detecon. It is applied to re-
prevenon purposes in scenic region, forest, tunnel and so on.
Fire Detecon
Congure
the re source detecon parameters. When re source is detected, the alarm acons
will be triggered.
Smoking Detecon
The device can detect the smoking behavior and output alarm.
4.1 Select Recommended Scene
Introduce the recommended scenes of re source detecon and help you select the appropriate
scene.
Fire source
detecon can be applied to indoor and outdoor monitoring with a maximum detecon
radius 15 km. To achieve the best monitoring eect, please set the installaon place as
requirements below.
The
installaon place should be the highest posion within the detecon area. The lens should
not be covered during movement to detect the maximum area.
It is
beer to choose the installaon place with convenient trac, well-equipped power and
internet facilies. E.g.: communicaon tower, watchtower, high-rise roof and so on.
4.2 Set Fire
Detecon Parameters
To avoid the potenal re damage, you should congure the re detecon funcon for certain
areas. The detail
conguraon steps show as below.
Before You Start
Go to Conguraon → System → Maintenance → VCA Resource Type , select Temperature
Measurement+Behavior Analysis or Temperature Measurement+Fire Detecon.
Steps
1. Go to Conguraon → Local .
2. Check Locate Highest Temperature Point to display the
posion of highest temperature. Check
Frame Fire Point to frame the re source on live view.
3. Go to
Conguraon → Event → Smart Event , select Dynamic Fire Source Detecon.
4. Check Enable Dynamic Fire Source Detecon.
5. Set the parameters of
re detecon.
Thermal & Opcal Bi-spectrum Network Camera User Manual
13