User's Manual
Table Of Contents
- Legal Information
- Symbol Conventions
- Safety Instruction
- Chapter 1 Overview
- Chapter 2 Device Activation and Accessing
- Chapter 3 Temperature Measurement
- Chapter 4 Fire Source Detection
- Chapter 5 Behavior Analysis
- Chapter 6 Event and Alarm
- Chapter 7 Arming Schedule and Alarm Linkage
- Chapter 8 Live View
- Chapter 9 Video and Audio
- 9.1 Video Settings
- 9.2 Display Settings
- 9.2.1 Image Adjustment
- 9.2.2 Image Adjustment (Thermal Channel)
- 9.2.3 Exposure Settings
- 9.2.4 Day/Night Switch
- 9.2.5 Set Supplement Light
- 9.2.6 BLC
- 9.2.7 WDR
- 9.2.8 White Balance
- 9.2.9 DNR
- 9.2.10 Defog
- 9.2.11 Set Palette
- 9.2.12 Set Target Color
- 9.2.13 DDE
- 9.2.14 Brightness Sudden Change
- 9.2.15 Enhance Regional Image
- 9.2.16 Mirror
- 9.2.17 Video Standard
- 9.2.18 Digital Zoom
- 9.2.19 Scene Mode
- 9.3 OSD
- 9.4 Set Privacy Mask
- 9.5 Overlay Picture
- 9.6 Set Manual DPC (Defective Pixel Correction)
- 9.7 Set Picture in Picture
- Chapter 10 Video Recording and Picture Capture
- Chapter 11 Network Settings
- Chapter 12 System and Security
- 12.1 View Device Information
- 12.2 Search and Manage Log
- 12.3 Import and Export Configuration File
- 12.4 Export Diagnose Information
- 12.5 Reboot
- 12.6 Restore and Default
- 12.7 Upgrade
- 12.8 View Open Source Software License
- 12.9 Time and Date
- 12.10 Set RS-232
- 12.11 Set RS-485
- 12.12 Set Same Unit
- 12.13 Security
- 12.14 User and Account
- Chapter 13 Appendix
Fire Source Detecon Mode
Smoking Mode
Detect smoking behavior in the scene.
Dynamic Fire
Detect the
re source in the scene.
Sensivity
The sensivity of re detecon. The bigger the value is, more easily the re source can be
detected, and the false rate is higher.
Note
When VCA Resource Type is selected as Temperature Measurement+Behavior Analysis, only
smoking detecon is supported. When VCA Resource Type is selected as Temperature
Measurement+Fire Detecon, two detecon modes are both supported.
6. Check Display Fire Source Frame on Stream to display a red frame around the re source on
stream when re occurs.
7. Oponal: you can shield certain areas from being detected in re source detecon.
1) Go to Conguraon → Event → Smart Event → Fire Source Detecon Shield .
2) Check Enable Fire Source Detecon Shield .
3) Click Draw Area and drag the mouse in the live view to draw the area. Release the mouse to
nish drawing.
4) You can drag the corners of the red rectangle area to change its shape and size. Or drag the
rectangle to the
posion on your demand.
5) Click Stop Drawing.
6) Click Clear All to clear all of the
seng areas.
7) Set the value of Acve Zoom Rao on your demand, and then the shield will only appear
when the zoom
rao is greater than the predened value
8) Click Add to save the smoke detecon shield, and it will be listed in the Fire Source Detecon
Shield List area; you can select a region and click Delete to delete it from the list; you can
also dene the color of the regions.
9) Check Display Shield Region to show the shielded area in live view.
8. Refer to Set Arming Schedule for
seng scheduled me. Refer to Linkage Method Sengs for
seng linkage method.
9. Click Save.
Thermal & Opcal Bi-spectrum Network Camera User Manual