User's Manual

Table Of Contents
Cauon
Separate 4
vercal lines in the opcal-axis direcon at the close site, middle and far site
respecvely.
Separate 4 vercal lines at the le, middle and right of the image respecvely.
If manual
calibraon's result is incorrect, select another target to recalibrate.
Aer manual calibraon, refer to Verify the Calibraon Result to verify if the calibraon is
successful.
Result
Aer calibraon, the height and angle of camera will be shown in live view.
5.3.3 Verify the
Calibraon Result
The funcon can verify whether the calibrated value is consistent with the actual value.
Steps
1. Click .
2. Click , and drag a vercal line in the view.
3. Move the line to the target, then click
to caculate the length.
Compare the calculated line length to the actual length to verify the calibraon sengs.
4. Click to exit.
Note
Verify not only person, but also other objects appeared in the view. Such as car, street lamp, etc.
5.4 Set Rules
The device can detect whether there is any target break the VCA rules. The opcal camera will
track the target or the device will alarm when the VCA rule is triggered.
Steps
1. Go to
Conguraon → VCA → Rule .
2. Click to add a new rule.
3. Enter the rule name, and click the drop down menu to select Rule Type.
Note
Each scene can be congured with dierent rule type. Up to 8 rules can be set for one scene.
Line Crossing
If any target move across the seng line, the alarm will be triggered. You can set the crossing
direcon.
Thermal & Opcal Bi-spectrum Network Camera User Manual
18