User's Manual

Table Of Contents
Note
You can draw the max size and min size rectangles according to the real target in the scene.
The recommended size is 1.2 mes of the target.
Due to the main dierence between human and animal is the height. Just concern the height
of animal.
Click
to copy the same sengs to other rules.
7. Click Save.
8.
Oponal: you can shield certain areas from being detected. Refer to Set Shielded Region for
detailed sengs.
Note
Repeat steps above to congure mulply rules. Set the arming schedule and linkage method for
each rule.
9. Refer to Set Arming Schedule for seng scheduled me. Refer to Linkage Method Sengs for
seng linkage method.
5.5 Advanced
Conguraon
Go to Conguraon → VCA → Advanced Conguraon and congure the parameters.
Detecon Parameters
Detecon Sensivity
The higher the sensivity is, the easier the target will be detected.
Background Update Rate
if a detected target remains in the monitoring scene for a certain me, the system will count the
target as the background
automacally. The greater the value is, the faster the target will be
counted as the background.
Minimum Target Size
The system will lter out the object smaller than the minimum target size.
Displacement Constraint for Target Generaon
The higher the value is, the slower the target is generated, and the higher accuracy the analysis
will get.
Opcal-axis Movement
Check the funcon when the target moves in the direcon of camera's opcal -axis.
When the target is far from the device and the movement is not clear, enable this funcon to
check the move
direcon.
Single Alarm
Thermal & Opcal Bi-spectrum Network Camera User Manual
20