Fire and Smoke Detection as VCA Resource Type.
2. Enter the fire and smoke detection interface:
Configuration > Event > Smart Event > Dynamic Fire Source Detection
Figure 5-23 Dynamic Fire Source Detection
3. Check the checkbox of Enable Dynamic Fire Source Detection.
The function of dynamic fire source detection can only be enabled for
camera 2.
4. Select the Application Scene from the list. Forest-Fire Prevention, Straw Burning,
High-building, and Indoor/Perimeter are selectable. Set the Installation Height for
scene if required.
5. Set the fire detection parameters:
Detection Mode: Select detection mode as by Multiple Frame, and the system
alarms with high accuracy. Select detection mode as by Single Frame, and the
system alarms with short delay.
Sensitivity: Range [1-100], the smaller the value is, the fire source of lower
temperature can be detected.
Hold-and-Alarm Mode: The system will stop when it detects the fire source. You
can set the duration while it keeps still.
- In Auto mode, you can set the dwell time, range [0-120]. During the dwell
time the camera stays still where it detects the fire source when
performing auto scan, patrol, pattern, scheduled task, and park action.
- In Manual Mode, the device stays still where it detects the fire source, until
you manually moves the camera.