User Manual
Table Of Contents
- Chapter 1 Overview
- Chapter 2 Network Connection
- Chapter 3 Access to the Network Speed dome
- Chapter 4 Basic Operations
- Chapter 5 System Configuration
- Chapter 6 VCA Configuration
- Chapter 7 Speed dome Configuration
- 7.1 Configuring Network Settings
- 7.2 Configuring Video and Audio Settings
- 7.3 PTZ Configuration
- 7.4 Configuring Image Settings
- 7.5 Configuring System Settings
- Appendix
User Manual of Thermal Network Speed dome
© Hikvision
62
Emissivity: Set the emissivity of your target. Note: The emissivity of each object
is different.
Distance (m): The straight-line distance between the target and the device.
Pre-Alarm: When the temperature of target exceeds the Pre-Alarm Threshold,
and this status keeps NOT shorter than the Filtering Time, it triggers the
Pre-Alarm.
Check the checkbox of Pre-Alarm Output to set link the pre-alarm with the
connected alarm device.
Alarm: When the temperature of target exceeds the Alarm Threshold, and this
status keeps NOT shorter than the Filtering Time, it triggers the Alarm.
Check the checkbox of Alarm Output to set link the pre-alarm with the
connected alarm device.
4. Click Save.
Expert Mode:
1. Enter Configuration > Temperature Measurement > Advanced Settings.
2. Select the temperature measurement and alarm configuration as Expert.
3. Adjust the PTZ.
Figure 5-27 Temperature Measurement Configuration
1) Adjust the image to the scene for temperature measurement with the PTZ control