User Manual

Table Of Contents
User Manual of Thermal Network Speed dome
© Hikvision
64
c) Set the Alarm Temperature, Pre-Alarm Temperature, and Tolerance
Temperature.
d) Set the Pre-Alarm Output and Alarm Output with the connected alarm
sensor and alarm device.
E.g., select Alarm Rule as Above (Average Temperature), and set the Alarm
Temperature to 50 ° C, and the device alarms when its average temperature is
higher than 50 ° C.
For Line Rule:
a) Click to show the Alarm Rule setting interface.
Figure 5-29 Alarm Rule Settings (Line)
b) Set the alarm rule.
c) Set the Alarm Temperature, Pre-Alarm Temperature, and Tolerance
Temperature.
d) Set the Pre-Alarm Output and Alarm Output with the connected alarm
sensor and alarm device.
E.g., select Alarm Rule as Above (Max. Temperature) and set the Alarm
Temperature to 40 ° C, and the device alarms when the maximum temperature
is higher than 40 °C.
For Area Rule:
Task 1.
a) Click to show the Alarm Rule setting interface.