Figure 5-30 Alarm Rule Settings (Area)
b) Set the alarm rule.
c) Set the Alarm Temperature, Pre-Alarm Temperature, and Tolerance
Temperature.
d) Set the Pre-Alarm Output and Alarm Output with the connected alarm
sensor and alarm device.
E.g., select Alarm Rule as Above (Max. Temperature) and set the Alarm
Temperature to 40 ° C, and the device alarms when the maximum temperature
is higher than 40 ° C.
Task 2.
For two alarm rules of area, you can set the alarm for area temperature
difference.
a) Set the area alarm rules.
b) Click to show the area temperature
difference alarm interface.
Figure 5-31 Area Temperature Difference Alarm
c) Select two rules to compare the saved areas.
d) Set the alarm rules and the temperature.
E.g., select Area 1 and Area 2, and set the comparison rule as Above (Max.
Temperature), and set the temperature difference threshold to 5 ° C. The device
alarms when the difference of two areas' maximum temperature is above 5 ° C.
e) Set the Alarm Output with the connected alarm sensor and alarm device.