Quick Start Guide

Thermometric Network Positioning System
ยทQuick Start Guide
12
- Route the power cord of external power source through sealing opening No.1,
and attach the cable with live wire and null wire from the power adapter
respectively.
- Connect the live wire to the L terminal of power surge protector, and connect
the null wire to the N terminal of power surge protector.
- Route the network cable from switch or client-end through sealing opening No.2,
and connect it to the network cable of the cable from positioning system.
- Route the cables from the positioning system through sealing opening No.3, and
connect the power cable to the power adapter.
Note: Make sure the 48 V DC+ terminal is connected to the positive terminal
of the power adapter and the 48 V DC- terminal is connected to the negative
terminal of the power adapter. The grounding terminal is connected to the
GND terminal of the adapter.
- Connect the reserved terminals to the rest cables of the positioning system.