User Manual

Table Of Contents
User Manual of Thermal Bi-spectrum Network PTZ Device
11
VCA Configuration.
Alarm Input and Output
Refer to the figure below to configure the alarm devices and sensors.
Alarm Device /Alarm
Sensor?
Start
Alarm Device
(e.g., siren)
Alarm Sensor (e.g.,
gas detector)
Connect to Alarm Output
Terminal (labeled ALARM OUT)
END
Connect your camera with the alarm device(s).
Connect to Alarm Input
Terminal (labeled ALARM IN)
Turn on the Camera. Turn on the Camera.
Go to Event>Basic Event>Alarm Output
and set the alarm.
Go to Event>Basic Event>Alarm Input
and set the alarm.
Set the schedule for the alarm device. Set the schedule for the sensor.
Link the alarm to e-mail,
center, alarm out , etc.
Set Alarm Linkage for events.
The functions vary depending on the models.
Bi-spectrum
The device has two lens, an optical one and a thermal one, and two images are respectively
provided by each lens.
PTZ Limits
The device can be programmed to move within the PTZ limits (left/right, up/down).
Scan Modes
The device provides 5 scan modes: auto scan, tilt scan, frame scan, random scan and panorama
scan.
Presets
A preset is a predefined image position. When the preset is called, the device will automatically
move to the defined position. The presets can be added, modified, deleted and called.
Label Display
The on-screen label of the preset title, azimuth/elevation, zoom, time and device name can be
displayed on the monitor. The displays of time and device name can be programmed.
Auto Flips
In manual tracking mode, when a target object goes directly beneath the device, the video will