User Manual
Table Of Contents
- Chapter 1 Overview
- Chapter 2 Network Connection
- Chapter 3 Access to the Network Device
- Chapter 4 Basic Operations
- Chapter 5 System Configuration
- Chapter 6 VCA Configuration
- Chapter 7 Device Configuration
- 7.1 Configure Network Settings
- 7.2 Configure Video and Audio Settings
- 7.3 Configure Image Settings
- 7.4 Configure System Settings
- Appendix
User Manual of Thermal Bi-spectrum Network PTZ Device
66
Display Temperature in Optical Channel: Check to display thermal channel temperature
information in the optical channel.
Display Max. Temperature: Check to display maximum temperature information in
thermal view when the temperature measurement rule is line or area.
Display Min. Temperature: Check to display minimum temperature information in
thermal view when the temperature measurement rule is line or area.
Display Average Temperature: Check to display average temperature information in
thermal view when the temperature measurement rule is line or area.
Position of Thermometry Info: Select the position of temperature measurement
information showed on the live view interface. Select Top Left to display the information
on the top left of screen. Select Near Target to display the information around the
temperature measurement rule.
Add Original Data on Capture: Check to add original data on capture.
Add Original Data on Stream: Check to add original data on stream.
Data Refresh Interval: Select the data refresh interval from 1s to 5s.
Unit: Display temperature with Degree Celsius (°C)/Degree Fahrenheit (°F)/Degree Kelvin
(K).
Temperature Range: Set the temperature range.
Version: View the version of current algorithm.
3. Clcik Save .
5.4.2 Temperature Measurement and Alarm
Purpose:
This function is used for measuring the temperature of detected spot and the device compares
temperature of selected regions and alarms.
Steps:
Normal Mode
1. Go to Configuration > Temperature Measurement > Advanced Settings.
2. Select the temperature measurement and alarm configuration as Normal.
3. Configure the parameters.