67
Figure 5-27 Temperature Measurement Configuration
Emissivity: Set the emissivity of your target.
The emissivity of each object is different.
Distance (m): The straight-line distance between the target and the device.
Pre-Alarm: When the temperature of target exceeds the Pre-Alarm Threshold, and
this status keeps NOT shorter than the Filtering Time, it triggers the Pre-Alarm.
Check Pre-Alarm Output to set link the pre-alarm with the connected alarm device.
Alarm: When the temperature of target exceeds the Alarm Threshold, and this status
keeps NOT shorter than the Filtering Time, it triggers the Alarm.
Check Alarm Output to set link the pre-alarm with the connected alarm device.
4. Click Save.
Expert Mode:
1. Enter Configuration > Temperature Measurement > Advanced Settings.
2. Select the temperature measurement and alarm configuration as Expert.
3. Adjust the PTZ.