For two alarm rules of area, you can set the alarm for area temperature difference.
a) Set the area alarm rules.
b) Click to show the area temperature
difference alarm interface.
Figure 5-32 Area Temperature Difference Alarm
c) Select two rules to compare the saved areas.
d) Set the alarm rules and the temperature.
E.g., select Area 1 and Area 2, and set the comparison rule as Above (Max.
Temperature), and set the temperature difference threshold to 5 °C. The device
alarms when the difference of two areas' maximum temperature is above 5 °C.
e) Set the Alarm Output with the connected alarm sensor and alarm device.
5.4.3 Linkage Method
Purpose:
Set the linkage method of the alarm.
Steps:
1. Go to Configuration > Temperature Measurement > Linkage Method.
2. Set the arming schedule and linkage method.
Arming Schedule: Click on the time bar and drag the mouse to select the time period.
Linkage Method: Click Linkage Method and check to select the linkage method. Audible
warning, notify surveillance center, send email, upload to FTP, trigger channel and
trigger alarm output are selectable. You can specify the linkage method when an event
occurs.
3. Click Save.
After the settings, you can view the current temperature and humidity on the top of this
interface.
5.4.4 Search History Temperature
Purpose:
Search the history temperature and generate the temperature/time graphic.
Steps: