If “Manually Clear” is selected in the dropdown list of Dwell Time, you can clear it only by going to Menu>
Manual> Alarm and clicking Clear All.
Figure 8. 24 Alarm Output Settings Interface
2. Set arming schedule of the alarm output.
Click to set the arming schedule of alarm output. Choose one day of a week and up to 8 time
periods can be set within each day.
Time periods shall not be repeated or overlapped.
Figure 8. 25 Set Arming Schedule of Alarm Output
3. Repeat the above steps to set up arming schedule of other days of a week. You can also click Copy to
copy an arming schedule to other days. Click OK to complete the settings of the alarm output.
4. You can also click Copy in Alarm Output interface to copy the above settings to another channel.
Figure 8. 26 Copy Settings of Alarm Output