User Manual
Table Of Contents
- Chapter 1 Introduction
- Chapter 2 Getting Started
- Chapter 3 Camera Management
- Chapter 4 Camera Settings
- Chapter 5 Live View
- Chapter 6 PTZ Control
- Chapter 7 Storage
- 7.1 Storage Device Management
- 7.2 Storage Mode
- 7.3 Recording Parameters
- 7.4 Configure Recording Schedule
- 7.5 Configure Continuous Recording
- 7.6 Configure Motion Detection Triggered Recording
- 7.7 Configure Event Triggered Recording
- 7.8 Configure Alarm Triggered Recording
- 7.9 Configure POS Event Triggered Recording
- 7.10 Configure Picture Capture
- 7.11 Configure Holiday Recording and Capture
- 7.12 Configure Redundant Recording and Capture
- Chapter 8 Disk Array
- Chapter 9 File Management
- Chapter 10 Playback
- Chapter 11 Event and Alarm Settings
- Chapter 12 VCA Event Alarm
- 12.1 Human Body Detection
- 12.2 Face Detection
- 12.3 Vehicle Detection
- 12.4 Line Crossing Detection
- 12.5 Intrusion Detection
- 12.6 Region Entrance Detection
- 12.7 Region Exiting Detection
- 12.8 Unattended Baggage Detection
- 12.9 Object Removal Detection
- 12.10 Audio Exception Detection
- 12.11 Sudden Scene Change Detection
- 12.12 Defocus Detection
- 12.13 PIR Alarm
- 12.14 Enable Smart Search
- Chapter 13 Smart Search
- Chapter 14 Human Body Detection
- Chapter 15 POS Configuration
- Chapter 16 Network Settings
- Chapter 17 Hot Spare Device Backup
- Chapter 18 System Maintenance
- Chapter 19 General System Settings
- Chapter 20 Appendix
Network Video Recorder User Manual
137
NUCLEUS
8) Click the Custom to configure the NUCLEUS settings.
9) Enter the employee No. shift No. and the terminal No. in the field. The matching message sent from
the POS device will be used as the valid POS data.
The NUCLEUS protocol must be used in the RS-232 connection communication.
Step 6 Select the connection mode to TCP Reception, UDP Reception, Multicast, RS-232,
USB-to-RS-232 or Sniff, and click Parameters to configure the parameters for each connection
mode.
TCP Connection
10) When using TCP connection, the port must be set from 1 to 65535, and the port for each POS
machine must be unique.
11) Set the Allowed Remote IP Address of the device sending the POS message.
Figure 15-4 TCP Connection Settings
UDP Connection
12) When using UDP connection, the port must be set from 1 to 65535, and the port for each POS
machine must be unique.
13) Set the Allowed Remote IP Address of the device sending the POS message.
USB-to-RS-232 Connection
Configure the port parameters of USB-to-RS-232 convertor, including the serial number of
port, baud rate, data bit, stop bit, parity and flow ctrl.