Quick Start Guide

Access Control Terminal·Quick Start Guide
31
When the access control terminal works as the RS-485 card reader, you should set serial port
parameters.
Steps:
1. Move the cursor to Serial (serial port settings) by using direction keys on the communication
settings interface.
2. Tap the # key to enter the serial port settings interface.
Figure 7-14 Serial Port Settings Interface
3. Modify parameters of the serial port, including working mode, Baud Rate, and RS-485 address.
Working Mode:
When the access control terminal working as the terminal, set the
working mode of the serial port to Connect to Reader, Connect to
Client or Connect to Unit.
If the terminal is worked as the card reader, the serial port is
connected to the terminal by default. There is no need to configure
the serial port working mode.
Baud Rate:
It will display the Baud Rate configured on the client software.
RS-485 Address:
When the access control terminal works as a card reader, the RS-485
address should be configured.
Tap the key to enter and exit the editing mode.
Tap the Right/Left direction keys to choose contents.
Tap the # key to switch the mode between Yes mode and No mode.
4. Move the cursor to the OK button, and tap the # key.
Reboot the device after changing the working mode.
7.3.3 Wiegand Settings
Purpose:
When the access control terminal works as the Wiegand card reader, you should set Wiegand
parameters.
Steps:
1. Move the cursor to Wiegand (Wiegand settings) by using direction keys on the communication
settings interface.
2. Tap the # key to enter the Wiegand settings interface.