Configuration Manual
Table Of Contents
- Legal Information
- Symbol Conventions
- 1 Local Operation
- 2 Remote Operation via the client software
- A. Communication Matrix and Device Command
Figure 2-11 Zone Alarm
2.
Select Zone No.
3.
Select Zone Type.
4.
Select Alarm Type.
5.
Set the NO/NC status.
6.
Set Entering Delay and Exing Delay.
7.
Select triggers.
8.
Click Save to enable zone sengs.
Note
•
7 zone types are supported: Emergency Switch, Door Magnec Switch,
Smoke Detector, Acve IR Detector, Passive IR Detector, Combusble Gas
Detector, and DoorBell Switch.
•
3 types of alarm mode are supported: Instant Alarm, 24H Alarm, and Delay
Alarm.
•
When the zone type is set to be Instant Alarm, only under arming mode, the
indoor staon will receive alarm message when the detector is triggered.
Under disarming mode, it will not receive alarm message when the detector
is triggered.
•
When the zone type is set to be 24H Alarm, the indoor
staon will receive
alarm message when the detector is triggered no maer it is under arming
mode or disarming mode.
Network Indoor
Staon Conguraon Guide