User Manual
7
Operaon Cauon and Device Maintenance
- All the electronic operaon should be strictly compliance with the electrical safety regulaons, fire prevenon regulaons and
other related regulaons in your local region.
- Do not drop the device or subject it to physical shock, and do not expose it to high electromagnesm radiaon. Avoid the
equipment installaon on vibraons surface or places subject to shock (ignorance can cause equipment damage).
- Please make sure that the power has been disconnected before you wire, install or dismantle the device.
- If smoke, odors or noise rise from the device, turn off the power at once and unplug the power cable, and then please contact
the service center.
- Do not drop the device or subject it to physical shock, and do not expose it to high electromagnesm radiaon. Avoid the
equipment installaon on vibraons surface or places subject to shock (ignorance can cause equipment damage).
- Do not place the device in extremely hot (refer to the specificaon of the device for the detailed operaon temperature), cold,
dusty or damp locaons, and do not expose it to high electromagnec radiaon.
- The device for indoor use shall be kept from rain and moisture.
Exposing the equipment to direct sun light, low venlaon or heat source such as heater or radiator is forbidden (ignorance can
cause fire danger).
- Do not aim the device at the sun or extra bright places. A blooming or smear may occur otherwise (which is not a malfuncon
however), and affecng the endurance of sensor at the same me.
- Improper use or replacement of the baery may result in hazard of explosion. Replace with the same or equivalent type only.
Dispose of used baeries according to the instrucons provided by the baery manufacturer.
- Do not expose the device to the corrosive gas. Otherwise the equipment damage may occur.
- Do not expose the device to the explosive situaon.
Hangzhou Hikvision Digital Technology CO.,Ltd. No.555 Qianmo Road, Binjiang District, Hangzhou 310052, China
5
Enable Silent Zone
Slide to green to make the zone keep
silent while alarm is triggered.
Funcon Descripon
Double Knock
Slide to green to make the zone alarm
with double knock.
Cross Zone
If the alarm triggered in both of the linked
zones within the set me, two alarm
messages will be reported.
Sensivity
Set the sensivity of the detector.
Higher sensivity makes the intruder easier
to be detected.
Image Resoluon
Set the resoluon of the image.
Image in Series
Set the captured image number in series.
Swinger limit acvaon
Set the limit mes of swinger acvion .
Trigger Interval, sec
Set the interval of trigger, and the alarm
message will not be repeated within the
me.
LED
Turn On/Off the LED.
Polling Rate
Set the interval of heartbeat.
Signal Strength Test
Enter the test mode, and view the LED
indicaon.
Detecon Zone Test
Enter the test mode, and start walk test.
Zone Bypass
By pass the zone.
Capture
Capture picture manully.