Quick Start Guide

Security Radar
Diagram References
ENGLISH
Indicator
Installaon
For detailed sengs, Scan the QR code to get the User Manual of Security Radar.
1. Download and install the iVMS-4200 client soware.
2. Enter Control Panel
- Modules Customizaon, select Radar, and click OK.
3. Enter Device Management page, select the radar in the Online Device List, click Modify Nenfo, change
the port as 80, and click Add to Client. If the network of the radar is not the same as the PC’s, click Add in the
Device for Management list and enter the radar IP address in the pop-up window to add the radar.
4. In iVMS-4200 client soware, enter Control Panel - Radar
.
5. Upload Map: Select a map, draw a path on the map and set the plong scale.
6. Expand the device group in the list on the le, and click and drag the radar onto the map.
7. Move along the edge of the required monitoring field. Make sure the target sign (red arrow) is moving within
the radar area (gray sector) shown on the added map. If the target sign is not within the sector, you need to
adjust the mounng posion or angle of the radar.
Power on the radar and make sure there is no large object in the monitoring area. Make the detector access
into the internet.
Test the radar aer installaon to make sure it is properly mounted.
1. In iVMS-4200 client soware, select the radar on Device Management page and click Remote Configuraon
to enter the configuraon page. You can also enter the device IP address in the web browser to enter the
configuraon page.
2. Click Smart Rule Sengs - Camera Linkage Sengs.
3. Click + to add cameras to the radar.
4. Select a camera in the Camera IP Address List, and select the radar zone or the trigger line (or whole field) in
the Zone Linkage list or the Trigger Line List.
5. Add the camera to iVMS-4200 client soware: In the client soware, enter Device Management page, click
Add
in the Device for Management list, and enter the IP address, user name and password of the camera in
the pop-up window.
1. Select a reference object about 50 m away from the speed dome. On the reference object, select a point
whose altude is the same as the speed dome’s.
2. Enter the IP address of the speed dome in the web browser to enter the web client. Adjust the PTZ buons
on the Live View page to make the reference object displayed in the image, and Click to zoom in the
reference object.
3. Click , and click the reference point to middle the point in the frame.
4. Enter Configuraon - PTZ - Inial Posion, and click Set to set the inial posion.
Link the camera to the Zone
Before calibraon, set the inial posion of the speed dome to ensure the tracking accuracy.
1. In iVMS-4200 client soware, enter Radar page, click
...
- Master-Slave Tracking Sengs.
2. Double click the radar in the list on the le. Click the live view window of the speed dome needs to be
calibrated, and click to maximum the window.
3. Select One Point Calibraon as the calibraon mode.
4. Ask the calibraon staff to move in the radar detecon field. Click the track of the calibrate staff, and the
color of the selected track will change from red to white.
5. Click Add to add a calibraon point.
6. Ask the calibraon staff to stand at the calibraon point within 20 to 40 m directly in front of the radar.
7. Click the added calibraon point in the list on the right to update the radar posion of the calibraon staff.
8. Adjust the PTZ buons in the live view window to update the PTZ posion: Click +/- to scale the calibraon
staff to a fit size (The altude of the calibraon staff is about 2/3 of the altude of the window), and adjust the
PTZ to make the object align with the sign + at the center of the frame. (For precise alignment, click , and
click on the center of the calibraon staff.)
Calibrate the Speed Dome
Calibraon
Inial Posion sengs
Enable Speed Dome Tracking
In iVMS-4200 client soware, enter the Master-Slave Tracking Sengs page, select the live view window of the
speed dome, and Check Enable Tracking.
Test
1
4
Wiring
3
Formang
2
5
Set Up
6
Specification
1. Aach the mounng bracket on the detector with four supplied screws.
2. Loosen the screws on both sides of the bracket.
3. Adjust the angle of the detector.
4. Tighten the screws on the both sides of the bracket to complete the installaon.
1. Aach the mounng bracket on the detector with four supplied screws.
2. Loosen the screws on both sides of the bracket.
3. Adjust the angle of the detector.
4. Tighten the screws on the both sides of the bracket to complete the installaon.
a. Power Supply Indicator
Solid Green: Detector Power on
b. Fault Alarm Indicator
Flashing Red: Fault Alarm Occurred, Solid Green:
Alarm Restored
c. Zone Alarm Indicator
Solid Red: Zone Alarm Occurred, Solid Green: Alarm
Restored
d. Formang Indicator
Red and green LED flashes 3 mes: Formang
Successfully
a. Alarm Output Wiring (Dry Contact Output)
a1: one for electrical load
a2: three for electronic load
b. Alarm Input Wiring (Reserved)
c. DC Power Supply Wiring
d. Ethernet (PoE port) Wiring
e. Grounding
Loosen the screws on the rear cover to remove the
cover. Hold the Reset buon while powering the
radar on unl the red and green LED flashes 3
mes.
Ceiling Mounng
Pole Mounng
Before You Start:
The recommended installaon height is 2.5 m.
Make sure that the mounng surface is strong enough to withstand at least 50N, as well as four mes the
weight of the device and the bracket.
1. In iVMS-4200 client soware, enter Control Panel - Radar.
2. Click
...
- Draw Zone Manually or Draw Trigger Line, and click the mouse to draw a zone or trigger line on the
radar detecon area.
3. Set the parameters of the zone or trigger line.
Zone: edit the zone parameters in the pop-up window. Click OK to finish the sengs.
Trigger Line: set the direcon of the line (le to right, right to le, or both way).Click Cancel to finish the
sengs.
Add Zone or Trigger Line for the Detector
If the speed dome is installed together with the radar, select the calibraon mode as One Point Calibraon.
Otherwise, set the calibraon as Mul-point Calibraon.
For one point calibraon, you can refer to the following steps, and see user manual for mul-point calibraon.
Note: You should acvate the device for the first usage. Select the device in the Online Device List, click
Acvate, create a password to acvate the device.
Scan the QR code to get the User Manual of Security Radar.
Note: The trigger line is not allowed to be crossed .
Before the operaon, you need to click the - on the Radar
page or right click the selected radar and
select disarm to disarm the radar.
1
1
2
2
3
4
Use only power supply listed below:
Manufacturer: Shenzhen HONOR Electronic Co., Ltd.
ModelADS-26FSG-12 12024EPG
COPYRIGHT ©2019 Hangzhou Hikvision Digital Technology Co., Ltd.
ALL RIGHTS RESERVED.
Any and all informaon, including, among others, wordings, pictures,
graphs are the properes of Hangzhou Hikvision Digital Technology Co.,
Ltd. or its subsidiaries (hereinaer referred to be “Hikvision”). This user
manual (hereinaer referred to be “the Manual”) cannot be reproduced,
changed, translated, or distributed, parally or wholly, by any means,
without the prior wrien permission of Hikvision. Unless otherwise
spulated, Hikvision does not make any warranes, guarantees or
representaons, express or implied, regarding to the Manual.
About this Manual
This Manual is applicable to the Security Radar.
The Manual includes instrucons for using and managing the product.
Pictures, charts, images and all other informaon hereinaer are for
descripon and explanaon only. The informaon contained in the Manual
is subject to change, without noce, due to firmware updates or other
reasons. Please find the latest version in the company website
(hp://overseas.hikvision.com/en/).
Please use this user manual under the guidance of professionals.
Trademarks Acknowledgement and other Hikvision’s
trademarks and logos are the properes of Hikvision in various
jurisdicons. Other trademarks and logos menoned below are the
properes of their respecve owners.
Product Informaon
This product and - if applicable - the supplied accessories too are
marked with "CE" and comply therefore with the applicable
harmonized European standards listed under the RE Direcve
2014/53/EU, the EMC Direcve 2014/30/EU, the LVD Direcve
2014/35/EU, the RoHS Direcve 2011/65/EU.
2012/19/EU (WEEE direcve): Products marked with this symbol
cannot be disposed of as unsorted municipal waste in the
European Union. For proper recycling, return this product to your
local supplier upon the purchase of equivalent new equipment,
or dispose of it at designated collecon points. For more
informaon see: www.recyclethis.info
2006/66/EC (baery direcve): This product contains a baery
that cannot be disposed of as unsorted municipal waste in the
European Union. See the product documentaon for specific
baery informaon. The baery is marked with this symbol,
which may include leering to indicate cadmium (Cd), lead (Pb),
or mercury (Hg). For proper recycling, return the baery to your
supplier or to a designated collecon point. For more informaon
see:www.recyclethis.info
This product operates in a European non-harmonised frequency band.
1 3
4
6
206.5
228.5
60.8
2
a
b
c
d
NC
NO
……
……
NO COM NC
NO COM NC
a
1
2
a
b
c
d
OSD
1
3
1
2
50 m
09-29-2018 16:50:20
+
+
3D
3D
09-29-2018 16:51:22
09-29-2018 16:51:22
+
H H=h h
Initial Position
09-29-2018 16:52:07
a
b
NO4
NC4
COM4
NO3
NC3
COM3
NO2
NC2
COM2
NO1
NC1
COM1
e
Product Security Radar
Detection Range Vehicle:150 m, Human:120 m
Horizontal Angle 120°
Max. Target Number 64
Zone 16
Trigger Line 4
Velocity Range -9.8 to 9.8 m/s
Range Measurement
Accuracy
±0.75 m
V
elocity Measurement
Accuracy
±0.1 m/s
A
ngle Measurement
Accuracy
±1°
3-ch weak current output: 0.5
A/125 VAC,breakdown voltage: 1
KV
1-ch strong current output: 10
A/240 VAC,breakdown voltage:
2.5 KV
A
larm Output
Netowrk Interface
1 RJ45 10M/100M self-adaptive,
supports POE
Communication
Protocol
Standard ISAPI protocol, NAL2300
protocol
HTTP, DNS, NTP, TCP, UDP, DHCP,
ARP, and SSH
Exception Detection
Tampering alarm
Moving alarm
Power Interface
802.3at standard POE or 12 VDC
The supplied power adapter is for
12 VDC power input.
Operation Temperature –40 to 65
Operation Humidity 10% to 90%
Dimension(W x H x D) 206*228*61 mm
Protection level IP67, IK09, NEMA 4X
Weight 1.9 kg
Installation
Bracket installation
Installation Height: 1.2 m to 4 m
Recommended height range: 2.5 m
Recommended vertical angle: 0°
OSD
!
!
!
1 (-24.29,42) (12,25,34)
1 (-19.79,34) (31,43,17)
a
b
Note: The track disappears if the calibraon staff is standing in place for more than 7 s. If the calibraon staff
does not move to the calibraon point when the track disappears, you need to ask the calibraon staff moves
again, and click the track of the calibraon staff to connue the calibraon.
Before the operaon, you need to disable the parking funcon, and set the inial posion of the speed
dome.
FCC Informaon
Please take aenon that changes or modificaon not expressly approved by the party responsible for compliance could void the user’s authority to operate the
equipment.
FCC compliance: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits
are designed to provide reasonable protecon against harmful interference in a residenal installaon. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the instrucons, may cause harmful interference to radio communicaons. However, there is no
guarantee that interference will not occur in a parcular installaon. If this equipment does cause harmful interference to radio or television recepon, which can
be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
—Reorient or relocate the receiving antenna.
—Increase the separaon between the equipment and receiver.
—Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
—Consult the dealer or an experienced radio/TV technician for help.
This equipment should be installed and operated with a minimum distance 20cm between the radiator and your body.
FCC Condions
This device complies with part 15 of the FCC Rules. Operaon is subject to the following two condions:
1. This device may not cause harmful interference.
2. This device must accept any interference received, including interference that may cause undesired operaon.
IC Informaon
Industry Canada ICES-003 Compliance
This device meets the CAN ICES-3 (B)/NMB-3(B) standards requirements.
Industry Canada ICES-003 Compliance
This device meets the CAN ICES-3 (B)/NMB-3(B) standards requirements.
This device complies with Industry Canada licence-exempt RSS standard(s). Operaon is subject to the following two condions:
(1) this device may not cause interference, and
(2) this device must accept any interference, including interference that may cause undesired operaon of the device.
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radioexempts de licence. L'exploitaon est autorisée aux deux condions
suivantes :
(1) l'appareil ne doit pas produire de brouillage, et
(2) l'ulisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est suscepble d'en compromere le fonconnement.
Under Industry Canada regulaons, this radio transmier may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmier
by Industry Canada. To reduce potenal radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically
radiated power (e.i.r.p.) is not more than that necessary for successful communicaon.
Conformément à la réglementaon d'Industrie Canada, le présent émeeur radio peut
fonconner avec une antenne d'un type et d'un gain maximal (ou inférieur) approuvé pour l'émeeur par Industrie Canada. Dans le but de réduire les risques de
brouillage radioélectrique à l'intenon des autres ulisateurs, il faut choisir le type d'antenne et son gain de sorte que la puissance isotrope rayonnée équivalente
(p.i.r.e.) ne dépasse pas l'intensité nécessaire à l'établissement d'une communicaon sasfaisante.
This equipment should be installed and operated with a minimum distance 20cm between the radiator and your body.
Cet équipement doit être installé et ulisé à une distance minimale de 20 cm entre le radiateur et votre corps.
UD15811B

Summary of content (1 pages)