User Manual

Table Of Contents
-
Check Priorize Display of Latest Alarm, the screen switches to 4-window mode and the
new alarm video will cyclically overlay 4 windows.
-
Click Prev Page or Next Page to view unread alarm messages.
-
Click
Congure to enter Storage Schedule page. For detailed conguraon, see Set Storage
Schedule via Storage Server .
-
Click Exit to exit the alarm window.
4. Oponal: Click to disable alarm triggered pop-up image.
Note
For more details, see User Manual of iVMS-4200 Client Soware.
5.5 Calibrate Camera
Calibrate the linked camera to ensure the accuracy of camera tracking.
Before You Start
You need to disarm the radar before the operaon. Right-click on the radar detecon area and
click Disarm to disarm the radar.
You need to link the speed dome to the zone before
calibraon, and set the speed dome inial
posion.
The installaon height of the linked speed dome should to be more than 3 m.
Steps
1. In the client soware, click Control Panel → Radar .
2. Click → Master-slave Tracking
Sengs on the upper-right corner of the page.
3. Double click the radar in the device list on the le. The live view window of the camera will be
displayed under the radar
eld diagram.
Security Radar User Manual
20