User Manual

Table Of Contents
Steps
1. In
calibraon page, select Mulpoint Calibraon as the Calibraon Mode.
2. Select
calibraon points (equally distributed) in the radar detecon eld, you can refer to the
following gure to select points.
Figure 5-14 Mulpoint Distribuon Instance
Note
It is required to set at least 4 calibraon points (equally distributed) when mulpoint
calibraon.
3. According to the calibraon points, ask the calibraon sta to move to a calibraon point, and
refer to step 2 to step 4 in One Point Calibraon to calibrate the calibraon point.
4. When the
rst calibraon point is calibrated completely, let the calibraon sta move to the
next calibraon point aer the yellow track disappears. And then refer to step 2 to step 4 in One
Point
Calibraon to calibrate the calibraon point. Follow this process to complete all calibraon
point posioning in turn.
Security Radar User Manual
28