User Manual
Table Of Contents
- Legal Information
- Symbol Conventions
- Chapter 1 Access to Client Software/Web Client
- Chapter 2 Activation
- Chapter 3 Wired Network Settings
- Chapter 4 Radar Settings
- Chapter 5 Camera Linkage Settings
- Chapter 6 Set Record and Storage Settings
- Chapter 7 Alarm Settings
- Chapter 8 Set Radar Advanced Function
- Chapter 9 View Alarm Information
- Chapter 10 System Management
- Appendix A. Radar Mounting Height Recommendation
- Appendix B. Formatting Description
- Appendix C. Indicator Description
- Appendix D. FAQ
- D.1 How to Achieve an Optimum Detection Range?
- D.2 How to Solve the Problem that the Radar is not Shown in the Device List on the Radar Page?
- D.3 How to Adjust the Sensitivity to Avoid False Alarm?
- D.4 How to Raise the Precision of Camera Tracking?
- D.5 How to Solve the Problem that No Reference Point is on the Frame While Setting the Speed Dome Initial Position?
- D.6 What is the Reason that Failed to Draw a Zone Automatically?
- D.7 What Makes a Failed Arming?
- D.8 Why Is It Required to Remove Reflective Objects from the Radar Area?
- D.9 Why Is the Camera Unable to Track the Target?
- D.10 Common Mistakes of Calibrating Camera
7.4 Set Alarm Output
Steps
1. Select the radar and click Remote Conguraon in the client soware, or enter the IP address
of the radar in the address bar of the web browser. Click Alarm Module Parameters → Relay to
enter the page.
Cauon
• 3-ch weak current alarm output: 0.5 A/125 VAC, breakdown voltage: 1 KV.
• 1-ch strong current alarm output: 10 A/240 VAC, breakdown voltage: 2.5 KV.
Figure 7-4 Relay
Note
You can also click Control Panel → Radar → → … → Alarm Output to open or close the relay.
2. Select an relay, and click to enter the page.
3. Edit the relay name, and output
me.
4. Set relay linkage. Link the relay with alarm event, system event, and arming/disarming
operaon.
5. Oponal: Check Enable Zone Tracking. When enabled, aer the relay-linked zone is triggered by
an alarm, the relay will remain open unl the target exits the zone or the alarm is manually
closed.
Note
Aer the zone tracking is turned on, if only the zone is selected in the alarm event, the relay
output me is based on the me when the alarm triggered in the zone.
6. Click OK to save.
7. Click Delete to delete a selected period. Click Delete All to delete all periods in the me table.
Security Radar User Manual
36