7.4 Set Alarm Output
Steps
1. Select the radar and click Remote Conguraon in the client soware, or enter the IP address
of the radar in the address bar of the web browser. Click Alarm Module Parameters → Relay to
enter the page.
Cauon
3-ch weak current alarm output: 0.5 A/125 VAC, breakdown voltage: 1 KV.
1-ch strong current alarm output: 10 A/240 VAC, breakdown voltage: 2.5 KV.
Figure 7-4 Relay
Note
You can also click Control Panel → Radar → → … → Alarm Output to open or close the relay.
2. Select an relay, and click to enter the page.
3. Edit the relay name, and output
me.
4. Set relay linkage. Link the relay with alarm event, system event, and arming/disarming
operaon.
5. Oponal: Check Enable Zone Tracking. When enabled, aer the relay-linked zone is triggered by
an alarm, the relay will remain open unl the target exits the zone or the alarm is manually
closed.
Note
Aer the zone tracking is turned on, if only the zone is selected in the alarm event, the relay
output me is based on the me when the alarm triggered in the zone.
6. Click OK to save.
7. Click Delete to delete a selected period. Click Delete All to delete all periods in the me table.
Security Radar User Manual