User Manual
Table Of Contents
- Legal Information
- Symbol Conventions
- Chapter 1 Access to Client Software/Web Client
- Chapter 2 Activation
- Chapter 3 Wired Network Settings
- Chapter 4 Radar Settings
- Chapter 5 Camera Linkage Settings
- Chapter 6 Set Record and Storage Settings
- Chapter 7 Alarm Settings
- Chapter 8 Set Radar Advanced Function
- Chapter 9 View Alarm Information
- Chapter 10 System Management
- Appendix A. Radar Mounting Height Recommendation
- Appendix B. Formatting Description
- Appendix C. Indicator Description
- Appendix D. FAQ
- D.1 How to Achieve an Optimum Detection Range?
- D.2 How to Solve the Problem that the Radar is not Shown in the Device List on the Radar Page?
- D.3 How to Adjust the Sensitivity to Avoid False Alarm?
- D.4 How to Raise the Precision of Camera Tracking?
- D.5 How to Solve the Problem that No Reference Point is on the Frame While Setting the Speed Dome Initial Position?
- D.6 What is the Reason that Failed to Draw a Zone Automatically?
- D.7 What Makes a Failed Arming?
- D.8 Why Is It Required to Remove Reflective Objects from the Radar Area?
- D.9 Why Is the Camera Unable to Track the Target?
- D.10 Common Mistakes of Calibrating Camera
Prompt when selecng target: Please select the calibraon target trajectory.
Reason: Target not selected or disappeared when acquiring parameters.
Soluon: Select the moving target for parameter acquision.
Prompt when adding calibraon points: Error in parameter range, illegal range: T <=0.
Reason: The angle of pitch, T, of the speed dome is less than or equal to 0.
Soluon: Adjust the angle of pitch of the speed dome so that T is greater than 0.
Prompt when adding calibraon points: Incorrect Parameters.
Reason: The status of the linked camera device is oine.
Soluon:
Reconnect the camera. Make the status of the camera is online to connue calibraon.