User Manual

Network Camera User Manual
93
such as human face, human body, and vehicle.
Note
For certain device models, you need to enable Multi-Target-Type Detection on VCA Resource
page first.
10.3.1 Set Multi-Target-Type Detection Rule
After setting the multi-target-type detection rules and algorithm parameters, the device captures
targets of multiple types and triggers linkage actions automatically.
Steps
1. Go to Configuration Multi-Target-Type Detection Rule.
2. Check Rule.
3. Click , and draw a detection area on live image.
4. Enter the min. pupil distance in the text field, or click to draw min. pupil distance.
Min. Pupil Distance
The min. pupil distance refers to the minimum area between two pupils, and it is basic for the
device to recognize a face.
5. Set arming schedule. See Set Arming Schedule.
6. Set linkage method. See Linkage Method Settings.
7. Click Save.
What to do next
Go to Picture to search and view the captured pictures.
Go to Smart Display to see currently captured target pictures.
10.3.2 Overlay and Capture
Choose to configure capture parameters and the information you want to display on stream and
picture.
Display VCA info. on Stream
Display smart information on stream, including the target and rules information.
Display Target info. on Alarm Picture
Overlay the alarm picture with target information.
Target Picture Settings
Custom, Head Shot, Half-Body Shot and Full-Body Shot are selectable.
Note
If you select Custom, you can customize width, head height and body height as required.
You can check Fixed Value to set the picture height.