User Manual

Network Camera User Manual
48
Figure 6-8 Set Rule
5. Optional: You can set the parameters of multiple areas by repeating the above steps.
6. For the arming schedule settings, refer to Set Arming Schedule. For the linkage method settings,
refer to Linkage Method Settings.
7. Click Save.
6.2.11 Set Object Removal Detection
It detects whether the objects are removed from the pre-defined detection region, such as the
exhibits on display. If it occurs, the device can take linkage actions and the staff can take measures
to reduce property loss.
Steps
1. Go to Configuration Event Smart Event Object Removal Detection.
2. Check Enable.
3. Select a Region. For the region settings, see Draw Area.
4. Set the rule.
Sensitivity
Range [1-100]. It stands for the percentage of the body part of an
acceptable target that leaves the pre-defined region.
Sensitivity = 100 S1/ST*100
S1 stands for the target body part that leaves the pre-defined region.
ST stands for the complete target body.
Example: If you set the value as 60, a target is possible to be counted
as a removed object only when 40 percent body part of the target
leaves the region.
Threshold
Range [5-100s], the threshold for the time of the objects removed
from the region. If you set the value as 10, alarm is triggered after the
object disappears from the region for 10s.