User Manual
Table Of Contents
- Chapter 1 System Requirement
- Chapter 2 Network Connection
- Chapter 3 Access to the Network Camera
- Chapter 4 Wi-Fi Settings
- Chapter 5 Live View
- Chapter 6 Network Camera Configuration
- Chapter 7 Network Settings
- 7.1 Configuring Basic Settings
- 7.2 Configure Advanced Settings
- 7.2.1 Configuring SNMP Settings
- 7.2.2 Configuring FTP Settings
- 7.2.3 Configuring Email Settings
- 7.2.4 Platform Access
- 7.2.5 Wireless Dial
- 7.2.6 HTTPS Settings
- 7.2.7 Configuring QoS Settings
- 7.2.8 Configuring 802.1X Settings
- 7.2.9 Integration Protocol
- 7.2.10 Bandwidth Adaptation
- 7.2.11 Network Service
- 7.2.12 Smooth Streaming
- 7.2.13 HTTP Listening
- Chapter 8 Video/Audio Settings
- Chapter 9 Image Settings
- Chapter 10 Event Settings
- 10.1 Basic Events
- 10.2 Smart Events
- 10.2.1 Configuring Audio Exception Detection
- 10.2.2 Configuring Defocus Detection
- 10.2.3 Configuring Scene Change Detection
- 10.2.4 Configuring Face Detection
- 10.2.5 Configuring Intrusion Detection
- 10.2.6 Configuring Line Crossing Detection
- 10.2.7 Configuring Region Entrance Detection
- 10.2.8 Configuring Region Exiting Detection
- 10.2.9 Configuring Unattended Baggage Detection
- 10.2.10 Configuring Object Removal Detection
- 10.3 VCA Configuration
- Chapter 11 Storage Settings
- Chapter 12 Playback
- Chapter 13 Picture
- Chapter 14 Application
- Chapter 15 Open Platform
- Chapter 16 Smart Display
- Appendix
Network Camera User Manual
165
b) Set parameters for the added region.
i. Set the region name and alarm interval.
Region Name: It is displayed as OSD information.
Alarm Interval: In the set alarm interval, alarms of the same type only
trigger one notification.
ii. Set regional people queuing-up settings.
Check OSD to display the region name and its real-time queuing-up
people number.
Alarm Trigger Condition: When the people number in the region is
greater than, less than, equal to or not equal to the set threshold, an
alarm is triggered.
Alarm threshold: An alarm is triggered when the alarm threshold
condition is met.
iii. Set waiting time detection settings.
Alarm Trigger Condition: When the people number in the region is
greater than, less than, equal to or not equal to the set threshold, an
alarm is triggered.
Alarm threshold: An alarm is triggered when the alarm threshold
condition is met.
c) Repeat above steps to set up other regions if needed. Up to 3 regions are
supported.
2. Arming Schedule.
Set the arming schedule for the function. In the armed periods, the function is
active. Refer to Task 2 in 10.1.1 Configuring Motion Detection.
3. Linkage Method. Set linkage method.
For triggered alarm information, you can set the linkage action as a response to
forward the information or trigger other actions. Refer to Task 3 in 10.1.1
Configuring Motion Detection.
4. Advanced Configuration.
(Optional) Check the queue management version and set the filtering