Yaw Angle The maximum yaw angle when starng face authencaon. By default,
the angle is 45°.
Pupillary Distance The minimum resoluon between two pupils when starng face
recognion. The actual resoluon should be larger than the congured
value.
By default, the resoluon is 40.
6.6 Data Management
You can import user list, export user list template, export enrolled data, and clear enrolled data.
6.6.1 Import User
Import the user informaon from the USB
ash drive to the device.
Before You Start
Plug the USB ash drive in the USB interface on the device.
Steps
1. Long tap on the inial page for 3 s and login the home page.
2. Tap Data.
Figure 6-15 Data Management Page
3. T
ap Export Template.
The template will be exported to the USB ash drive.
4. E
dit the exported table and enroll the user informaon.
Note
Make sure the edited le is saved in the root directory of the USB ash drive.
Requirements of face picture: It should be taken in full-face view, directly facing the camera.
Do not wear a hat or head covering when taking the face picture. The format should be JPEG