Parameter Descripon
Note
Only the device with the ngerprint module supports the
ngerprint related funcon.
Biometric recognion products are not 100% applicable to
an-spoong environments. If you require a higher security
level, use mulple authencaon modes.
If you adopt mulple authencaon modes, you should
authencate other methods before authencang face.
Sub Reader Auth Select the card reader's authencaon mode.
Door Contact You can select "Remain Open" or "Remain Closed" according to
your actual needs. By default, it is Remain Closed.
Open Duraon Set the door unlocking duraon. If the door is not opened for
the set me, the door will be locked. Available door locked me
range: 1 to 255s.
Door-Open Timeout Alarm Congure the maximum me duraon for door opening. If the
door-open me has exceeded the congured value, it will trigger
an alarm.
Auth Times Exceeded Alarm Congure the maximum mes for authencaon.
Super Password Set the device super password. Aer saving the sengs, you can
input the super password in the inial interface to access the
door.
6.7 Basic Sengs
6.7.1 Set System Parameters
Set the system parameters, including the device me format, the keypad sound, the voice prompt,
the volume, and the sleeping mode.
Steps
1. Move the cursor and select System → System .
2. Press * to enter the System page.
Access Control Terminal User Manual