User's Manual

Note
Up to 80 bits are allowed in the total length.
The odd parity start bit, the odd parity length, the even parity start bit and the even parity
length range from 1 to 80 bit.
The start bit of the card ID, the manufacturer code, the site code, and the OEM should range
from 1 to 80 bit.
6. Set output transformaon rule.
1) Click Set Rule to open the Set Output Transformaon Rules window.
Figure 7-6 Set Output Transformaon Rule
2) Select rules on the le list.
The selected rules will be added to the right list.
3) Oponal: Drag the rules to change the rule order.
4) Click OK.
5) In the Custom Wiegand tab, set the rule's start bit, length, and the decimal digit.
7. Click Save.
7.7.5 Congure Card Reader Authencaon Mode and Schedule
You can set the passing rules for the card reader of the access control device according to your
actual needs.
Access Control Terminal User Manual