User's Manual

Table Of Contents
The door contact can be enabled with appropriate delay aer person with extended accesss
needs swipes her/his card.
Door Le Open Timeout Alarm
The alarm can be triggered if the door has not been closed in a congured me period. If it is
set as 0, no alarm will be triggered.
Lock Door when Door Closed
The door can be locked once it is closed even if the Door Locked Time is not reached.
Duress Code
The door can open by inpung the duress code when there is duress. At the same me, the
client can report the duress event.
Super Password
The specic person can open the door by inpung the super password.
Dismiss Code
Create a dismiss code which can be used to stop the buzzer of the card reader (by entering
the dismiss code on the keypad).
Note
The dur
ess code, super code, and dismiss code should be dierent.
The duress code, super password, and the dismiss code should be dierent from the
authencaon password.
The length of duress code, super password, and the dismiss code is according the device,
usually it should contains 4 to 8 digits.
5.
Click OK.
6.
Oponal: Click Cop
y to , and then select the door/oor(s) to copy the parameters in the page to
the selected doors/oor(s).
Note
The door or oor's status duraon
sengs will be copied to the selected door/oor(s) as well.
Congure Parameters for Card Reader
Aer adding the access control device, you can congure its card reader parameters.
Be
fore You Start
Add access control device to the client.
Steps
1.
Click Access Control → Advanced Funcon → De
vice Parameter .
2.
In the device list on the le, click
to expand the door, select a card reader and you can edit the
c
ard reader's parameters on the right.
3.
Edit the card reader basic parameters in the Basic Informaon page.
DS-K1T320 Series Face
Recoginon Terminal User Manual
123