Use only power supplies listed in the user instrucons:
Network Interface
When connecng door magnec sensor and exit
buon, the device and the RS-485 card reader
should use the common ground connecon.
The Wiegand terminal here is a Wiegand input
terminal. You should set the face recognion
terminal’s Wiegand direcon to “Input”. If you
should connect to an access controller, you should
set the Wiegand direcon to “Output”. For details,
see Seng Wiegand Parameters in Communicaon
Sengs in the user manual.
The suggested external power supply for door lock
is 12 V, 1A.
The suggested external power supply for Wiegand
card reader is 12 V, 1 A.
For wiring the fire module, see the user manual.
Do not wire the device to the electric supply directly.
If the interface for network connecon is too large,
you can use the supplied cable as shown below.
Connect
Network
Interface of
Device
Connect
Network
Cable
The figures are for reference only.
2 mm
23 mm
1.2 mm
85 mm
166 mm
8 mm
10 mm
24.5 mm
15.5 mm
microUSB Interface
(microUSB to USB cable included)
Loudspeaker
Indicator
IndicatorCamera
Debugging Port
(For debugging only)
Tamper
Wiring
Terminal
Network
Interface
Touch Screen
IR Light
Microphone
IR Light
Card
Presenng
Area
1
Appearance
Description of Indicator:
Default: Solid green.
Authenticated: Green light flashes for 3 times.
Authentication Failed: Green light turns off for 3 s.
RS-485
Wiegand
Door Lock
Power Input
Model
Manufacture
Standard
ADS-26FSG-12 12024EPG
Shenzhen Honor Electronic Co.,Ltd
PG
MSA-C2000IC12.0-24P-DE MOSO Technology Co.,Ltd PDE
ADS-26FSG-12 12024EPB Shenzhen Honor Electronic Co.,Ltd PB
ADS-26FSG-12 12024EPCU/EPC
Shenzhen Honor Electronic Co.,Ltd
PCU
ADS-26FSG-12 12024EPI-01
Shenzhen Honor Electronic Co.,Ltd
PI
ADS-26FSG-12 12024EPBR
Shenzhen Honor Electronic Co.,Ltd
PBR
GND
GND
GND
GND
BUTTON
12V External
Power Supply
Wiegand
Card Reader
-
+
Group B
Group D
B1
B2
B3
C1
C2
C3
D6
D7
D1
D2
D3
D4
D5
(NC)
(NO)
Electric Dropbolt
Power Supply
Electric Strike
Door Contact
Exit Button
White/Black
White/Purple
White/Yellow
White/Red
Yellow/Green
Yellow/Gray
Yellow/Black
Black
Red/Black
Black
Yellow
Green
White
Blue
Red
NO
COM
NC
NO
COM
NC
3.1
Device Wiring (Normal)
©2020 Hangzhou Hikvision Digital Technology Co., Ltd.
It includes instrucons on how to use the Product. The soware embodied in the Product is
governed by the user license agreement covering that Product.
About this Manual
This Manual is subject to domesc and internaonal copyright protecon. Hangzhou Hikvision
Digital Technology Co., Ltd. (“Hikvision”) reserves all rights to this manual. This manual cannot be
reproduced, changed, translated, or distributed, parally or wholly, by any means, without the
prior wrien permission of Hikvision.
Trademarks
and other Hikvision marks are the property of Hikvision and are registered
trademarks or the subject of applicaons for the same by Hikvision and/or its affiliates. Other
trademarks menoned in this manual are the properes of their respecve owners. No right of
license is given to use such trademarks without express permission.
Legal Disclaimer
TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, THE PRODUCT DESCRIBED, WITH ITS
HARDWARE, SOFTWARE AND FIRMWARE, IS PROVIDED “AS IS”, WITH ALL FAULTS AND ERRORS,
AND HIKVISION MAKES NO WARRANTIES, EXPRESS OR IMPLIED, INCLUDING WITHOUT
LIMITATION, MERCHANTABILITY, SATISFACTORY QUALITY, FITNESS FOR A PARTICULAR PURPOSE,
AND NON-INFRINGEMENT OF THIRD PARTY. IN NO EVENT WILL HIKVISION, ITS DIRECTORS,
OFFICERS, EMPLOYEES, OR AGENTS BE LIABLE TO YOU FOR ANY SPECIAL, CONSEQUENTIAL,
INCIDENTAL, OR INDIRECT DAMAGES, INCLUDING, AMONG OTHERS, DAMAGES FOR LOSS OF
BUSINESS PROFITS, BUSINESS INTERRUPTION, OR LOSS OF DATA OR DOCUMENTATION, IN
CONNECTION WITH THE USE OF THIS PRODUCT, EVEN IF HIKVISION HAS BEEN ADVISED OF THE
POSSIBILITY OF SUCH DAMAGES.
REGARDING TO THE PRODUCT WITH INTERNET ACCESS, THE USE OF PRODUCT SHALL BE WHOLLY
AT YOUR OWN RISKS. HIKVISION SHALL NOT TAKE ANY RESPONSIBILITIES FOR ABNORMAL
OPERATION, PRIVACY LEAKAGE OR OTHER DAMAGES RESULTING FROM CYBER ATTACK, HACKER
ATTACK, VIRUS INSPECTION, OR OTHER INTERNET SECURITY RISKS; HOWEVER, HIKVISION WILL
PROVIDE TIMELY TECHNICAL SUPPORT IF REQUIRED.
SURVEILLANCE LAWS VARY BY JURISDICTION. PLEASE CHECK ALL RELEVANT LAWS IN YOUR
JURISDICTION BEFORE USING THIS PRODUCT IN ORDER TO ENSURE THAT YOUR USE CONFORMS
THE APPLICABLE LAW. HIKVISION SHALL NOT BE LIABLE IN THE EVENT THAT THIS PRODUCT IS
USED WITH ILLEGITIMATE PURPOSES.
IN THE EVENT OF ANY CONFLICTS BETWEEN THIS MANUAL AND THE APPLICABLE LAW, THE LATER
PREVAILS.
Data Protecon
During the use of device, personal data will be collected, stored and processed. To protect data,
the development of Hikvision devices incorporates privacy by design principles. For example, for
device with facial recognion features, biometrics data is stored in your device with encrypon
method; for fingerprint device, only fingerprint template will be saved, which is impossible to
reconstruct a fingerprint image.
As data controller, you are advised to collect, store, process and transfer data in accordance with
the applicable data protecon laws and regulaons, including without limitaon, conducng
security controls to safeguard personal data, such as, implemenng reasonable administrave and
physical security controls, conduct periodic reviews and assessments of the effecveness of your
security controls.
Scan the QR code to get the user manual
for detailed informaon.
Note that mobile data charges may apply
if Wi-Fi is unavailable.
Apply Silicone sealant
among the cable wiring
area to keep the
raindrop from entering.
You can also install the device on the
wall or other places without the gang box.
For details, refer to the User Manual.
5
Apply Silicone sealant among the joints
between the device rear panel and the
wall (except the lower side) to keep the
raindrop from entering.
Apply
Silicone
Sealant
2
Wall Mounting:
Direct
Sunlight
Direct Sunlight
through Window
Backlight
Indirect Sunlight
through Window
Close to Light
1
Make sure the gang box is installed on the wall.
3
Align the device with the mounng
plate and hang the terminal on the
mounng plate.
Make sure the two sheets on each
side of the mount plate have been
in the holes at the back of the device.
4
Use the supplied hex key to secure the
2 screws at the boom of the device.
Use supplied screws to secure the mounng plate on the gang box.
Use another one supplied screw to secure the mounng plate on
the wall.
Route the cables through the cable hole of the mounng plate,
and connect to the corresponding external devices’ cables.
Installation Environment:
Indoor and outdoor installaon are supported. If installing the device
indoors, the device should be at least 2 meters away from the light, and at
least 3 meters away from the window or the door. If installing the device
outdoors, you should apply Silicone sealant among the cable wiring area
to keep the raindrop from entering.
The addional force shall be equal to three mes the weight of the equipment
but not less than 50N. The equipment and its associated mounng means shall
remain secure during the installaon. Aer the installaon, the equipment, including
any associated mounng plate, shall not be damaged.