User's Manual

Table Of Contents
Extended Open Duraon
The door contact can be enabled with appropriate delay aer person with extended access
needs swipes her/his card.
Duress Code
The door can open by inpung the duress code when there is duress. At the same me, the
client can report the duress event.
Dismiss Code
Create a dismiss code which can be used to stop the buzzer of the card reader (by entering
the dismiss code on the keypad).
Note
The duress code, super code, and dismiss code should be dierent.
The duress code, super password, and the dismiss code should be dierent from the
authencaon password.
The length of duress code, super password, and the dismiss code is according the device,
usually it should contains 4 to 8 digits.
5.
Click OK.
6.
Oponal: Click Copy to , and then select the door to copy the parameters in the page to the
selected doors.
Note
The door's status duraon sengs will be copied to the selected door as well.
Congure Parameters for Card Reader
Aer adding the access control device, you can congure its card reader parameters.
Steps
1.
Click Access Control → Advanced Funcon → Device Parameter .
2.
In the device list on the
le, click to expand the door, select a card reader and you can edit the
card reader's parameters on the right.
3.
Edit the card reader basic parameters in the Basic
Informaon page.
Note
The displayed parameters may vary for dierent access control devices. There are part of
parameters listed as follows. Refer to the user manual of the device for more details.
Some of the following parameters are not listed in the Basic Informaon page, click More to
edit the parameters.
Name
Edit the card reader name as desired.
Access Control Terminal User Manual
98