User's Manual

Table Of Contents
Elevator Control
Steps
1.
Click
Conguraon → Access Control → Elevator Control Parameters .
2.
Check Enable Elevator Control.
3.
Set the elevator parameters.
Elevator No.
Select an elevator No. for
conguraon from the drop-down list.
Elevator Controller Type
Select an elevator controller from the drop-down list.
Interface Type
Select a communicaon type from the drop-down list for elevator communicaon.
If you select RS-485, make sure you have connected the device to the elevator controller with
RS-485 wire.
If you select Network Interface, enter the elevator controller's IP address, port No., user
name, and password for
communicaon.
Negave
Floor Capacity
Set the negave oor number.
Note
Up to 4 elevator controllers can be connected to 1 device.
Up to 10 negave oors can be added.
Make sure the interface types of elevator controllers, which are connected to the same
device, are consistent.
Set RS-485 Parameters
You can set the RS-485 parameters including the peripheral, address, baud rate, etc.
Click
Conguraon → Access Control → RS-485 Sengs .
Check Enable RS-485, and set the parameters.
Click Save to save the sengs aer the conguraon.
No.
Set the RS-485 No.
Peripheral Type
Select a peripheral from the drop-down list according the actual situaon. You can select from
Card Reader, Extension Module, Access Controller, or Disable.
Access Control Terminal User Manual