User's Manual

Table Of Contents
Input
The device can connect a Wiegand card reader.
Output
The can connect an external access controller. And the two devices will transmit the card No.
via Wiegand 26 or 34.
4.
Drag the block to set the me interval and pulse width.
Note
The me interval ranges from 1 ms to 20 ms.
The pulse width ranges from 1 us to 100 us.
5.
Click Save to save the sengs.
Note
If you change the peripheral, and aer you save the device parameters, the device will reboot
automacally.
7.7.19 Video Intercom Sengs
Set Video Intercom Parameters
The device can be used as a door staon, outer door staon, or access control device. You should
set the device No. before usage.
Click
Conguraon → Intercom → Device No. .
If set the device type as Door
Staon or Access Control Device, you can set the oor No., door
staon No., and click Advanced Sengs to set Community No., Building No., and Unit No.
Click Save to save the sengs aer the conguraon.
Device Type
The device can be used as a door staon or outer door staon. Select a device type from the
drop-down list.
Note
If you change the device type, you should reboot the device.
Floor No.
Set the device installed oor No.
Door Staon No.
Set the device installed oor No.
Access Control Terminal User Manual
43