User's Manual

Table Of Contents
607 Series Face Recognition Terminal User Manual
76
Parameter
Description
ECO Mode (1:1)
Set the matching threshold when authenticating via ECO
mode 1:1 matching mode. The larger the value, the smaller
the false accept rate and the larger the false rejection rate.
By default, the value is 75.
ECO Mode (1:N)
Set the matching threshold when authenticating via ECO
mode 1:N matching mode. The larger the value, the smaller
the false accept rate and the larger the false rejection rate.
By default, the value is 84.
ECO Mode Threshold
When enabling the ECO mode, you can set the ECO mode’s
threshold. The larger the value, the easier the device
entering the ECO mode. Available range: 0 to 8.
Work Mode
Set the device work mode as Access Control Mode.
The access control mode is the device normal mode. You
should authenticate your credential for accessing.
Configuring Face Picture Parameters
Click Other Face Picture Parameters to enter the Configuring Face Picture Parameters page. You
can set the face picture parameters when authenticating. Click Save to save the settings.
The parameters descriptions are as follows:
Parameter
Description
Min. Detection Width
(Close to)
When the distance between the camera and the user is
short, the parameter represents the minimum
percentage of the facial width in the total width of the
recognition area.
The actual percentage should be larger than the
configured value when face picture authentication. In
this condition, the device will not detect other
parameters.
Pitch Angle
The maximum pitch angle when face authentication.
By default, the angle is 30°.
Yaw Angle
The maximum yaw angle when face authentication.
By default, the angle is 45°.
Min. Detection Area
(Width)
When the distance between the camera and the user is
long, the parameter represents the minimum
percentage of the facial width in the total width of the
recognition area.
The actual percentage should be larger than the
configured value when face picture authentication.
Other percentages, distances and angles in this table
should also meet their conditions.
Recommended Value: 14
Min. Detection Area
When the distance between the camera and the user is