User's Manual

Table Of Contents
Group No. Funcon Color Name Descripon
Group D D1 Door Lock White/Purple NC Lock Wiring
(NC)
D2 White/Yellow COM Common
D3 White/Red NO Lock Wiring
(NO)
D4 Yellow/Green SENSOR Door Contact
D5 Black GND Ground
D6 Yellow/Gray BUTTON Exit Door
Wiring
D7 Yellow/Black GND Ground
4.2 Wire Normal Device
You can connect the terminal with normal peripherals.
Figure 4-1 Device Wiring
Note
You should set the face
recognion terminal's Wiegand direcon as Input to connect to a
Wiegand card reader. If connects to an access controller, you should set the Wiegand direcon as
Output to transmit authencaon informaon to the access controller.
For details about Wiegand direcon sengs, see Set Wiegand Parameters .
DS-K1T642 Series Face Recognion Terminal User Manual
7