User's Manual

Table Of Contents
Figure 6-7 Set RS-485 Parameters
3. Select an peripheral type according to your actual needs.
Note
If you select Access Controller: If connect the device to a terminal via the RS-485 interface, set
the RS-485 address as 2. If you connect the device to a controller, set the RS-485 address
according to the door No.
4. Tap the back icon at the upper le corner and you should reboot the device if you change the
parameters.
6.4.4 Set Wiegand Parameters
You can set the Wiegand transmission direcon.
Steps
1. Tap Comm. (Communicaon Sengs) on the Home page to enter the Communicaon Sengs
page.
2. On the Communicaon Sengs page, tap Wiegand to enter the Wiegand tab.
Figure 6-8 Wiegand Sengs
3. Enable the Wiegand funcon.
4. Select a transmission direcon.
Output: A face recognion terminal can connect an external access controller. And the two
devices will transmit the card No. via Wiegand 26 or Wiegand 34.
Input: A face
recognion terminal can connect a Wiegand card reader.
5. Tap
to save the network parameters.
Note
If you change the external device, and aer you save the device parameters, the device will
reboot automacally.
DS-K1T642 Series Face Recognion Terminal User Manual
22