User's Manual

Table Of Contents
4.4.2 Normal/Study Mode Sengs
Set normal mode or study mode for device via buon or DIP switch.
Set Study Mode via Buon
Enter the study mode through buon conguraon to set the closed posion of the device barrier.
Steps
1.
Set the conguraon No. to "1" and the parameter to "2".
The device enters study mode.
2.
Power o the device and swing the barrier unl it is vercal to the pedestal.
3.
Power on the device.
The device will remember the current posion automacally.
4.
Reboot the device when you hear "Study accomplished. Please reboot."
Set Study Mode
Enter the study mode through DIP switching to set the closed posion of the device barrier.
Steps
1.
Set The No.1 of the 2-digit DIP Switch on the access control board to ON by referring the
following gure
to enter the study mode.
DS-K3B220X Series Swing Barrier User Manual
26