User's Manual
Table Of Contents
- Legal Information
- Regulatory Information
- Safety Instruction
- Available Models
- Chapter 1 Overview
- Chapter 2 System Wiring
- Chapter 3 Installation
- Chapter 4 General Wiring
- 4.1 Components Introduction
- 4.2 Wiring
- 4.3 Terminal Description
- 4.3.1 Main Lane Control Board Terminal Description
- 4.3.2 Sub Lane Control Board Terminal Description
- 4.3.3 Access Control Board Terminal Description
- 4.3.4 Sub Optional Board Terminal Description (Optional)
- 4.3.5 Card Reader Board Terminal Description
- 4.3.6 Main Optional Board Terminal Description (Optional)
- 4.3.7 General Wiring
- 4.3.8 RS-485 Wiring
- 4.3.9 RS-232 Wiring
- 4.3.10 Alarm Input Wiring
- 4.3.11 Exit Button Wiring
- 4.4 Device Settings
- Chapter 5 Activation
- Chapter 6 Operation via Web Browser
- 6.1 Login
- 6.2 Live View
- 6.3 Person Management
- 6.4 Search Event
- 6.5 Configuration
- 6.5.1 View Device Information
- 6.5.2 Set Time
- 6.5.3 Set DST
- 6.5.4 Change Administrator's Password
- 6.5.5 Online Users
- 6.5.6 View Device Arming/Disarming Information
- 6.5.7 Network Settings
- 6.5.8 Event Linkage
- 6.5.9 Access Control Settings
- 6.5.10 Turnstile
- 6.5.11 Card Settings
- 6.5.12 Set Privacy Parameters
- 6.5.13 Upgrade and Maintenance
- 6.5.14 Device Debugging
- 6.5.15 Component Status
- 6.5.16 Log Query
- 6.5.17 Certificate Management
- Chapter 7 Client Software Configuration
- 7.1 Configuration Flow of Client Software
- 7.2 Device Management
- 7.3 Group Management
- 7.4 Person Management
- 7.5 Configure Schedule and Template
- 7.6 Set Access Group to Assign Access Authorization to Persons
- 7.7 Configure Advanced Functions
- 7.8 Door/Elevator Control
- Appendix A. DIP Switch
- Appendix B. Button Configuration Description
- Appendix C. Event and Alarm Type
- Appendix D. Table of Audio Index Related Content
- Appendix E. Error Code Description
- Appendix F. Communication Matrix and Device Command
Figure 4-22 Enable Keyfob Paring Mode
3.
P
ower on the turnsle and it will enter the keyfob pairing mode.
4.
Hold the Close buon for more than 10 seconds.
The keyfob's indicator of the will ash twice if the pairing is completed.
5.
Set the No.2 switch to the OFF side, and reboot the turnsle to take eect.
Note
●
Only one turnsle can pair the keyfob. If mulple turnsles are in the pairing mode, the
k
eyfob will select only one of them to pair.
●
For details about DIP switch value and meaning, see
DIP Switch Descripon .
6.
Oponal: Go t
o System → User → Keyfob User on the remote control page of the client
soware to delete the keyfob.
4.4.4 Inialize Device
Steps
1.
Hold the inializaon buon on the access control board for 5 s.
Figure 4-23 Inializaon
Buon Posion
2.
The device will start restoring to factory sengs.
3.
When the pr
ocess is nished, the device will beep for 3 s.
Cauon
The
inializaon of the device will restore all the parameters to the default seng and all the
device events are deleted.